deleted by creator


deleted by creator
You can have a hosted e-mail system with your own domain, many service providers will do this. They would have the storage, archive, etc. on their servers. Access would be a web client, e-mail client of your choice, or a bridge demon. Option 2 is a hosted vertual server, so your self hosting but renting a VM server on a providers data center, they take care of the hardware, power, backup (sometimes depending on service), etc. You would set up your OS and e-mail services.
I use a combo of this, I have a service with my own domain and point my MX records there, I use a bridge and a sctipt to pull backups and store them locally but use their email clients for mobile and Thunderbird on PCs.
Edit: FWIW I’ve been using Proton (paid version) for this but will be moving to hosted virtual server at some point, when I get a minute to migrate. I expect the cost to be about the same


I can’t see the letter anymore (the site seems to be down) but unless this is a published public API or they have a public “bug bounty” program and the API was following the rules of engagement, and it did not sound like either was true, then this is hacking and illegal, at least in the jusidiction I’m in.


The next step should be to press charges on openAI, unauthorized hacking into computer systems is illegal.


Just turn it until the notch aligned with the screw, then unscrew the screw while pressing in slightly on the side of the notch.
Edit: That second picture in your original post shows the notches aligned with the screws, so it should be that way. You could take a playing card and try to slip it between the two see if there is anything binding it.


Your welcome, glad its working for you again :)
LOL, it’s gonna get worse,
–Does he know about the AI thing?
–Tell him about the AI thing.
Yeah, it’s gonna get worse.


I don’t think that’s correct, I’ve been using /e/OS since the version 1.x.x era. The app store has always sourced from google play anonomuouslly and from FDroid. And there has always been an option to use a Google account if you wanted to for paid apps (never used that as I don’t have Google accounts). It’s not a change or a secret.
Just mindlessly sending back this URL to someone that sent you a bunch of AI slop is the same thing they are complaining about, making your “brain a gizmo”.


By helping someone else out with a subject you know about when there is an opertunity. i.e. pay it forward. To quote Bill & Ted “Be excellent to each other”


It’s possible that the controller is identifying an open coil and not filling, you should get an error code right away if so. it’s also likely that you did not get a connector seated correctly when re-assembling or that the float switch is stuck from having it tippled over. Check all the connections and after setting it back up right, check that that the float switch can move up and down freely.


You have a dead coil you will have to replace the motor.


Looks like there are 3 coils wired in a Y formation, so the silver rectangles are where the electrical contact is made, let’s call them 1,2, and 3. If you measure across any 2 points you should get the same ( or close) ohm reading. In this set up you are measuring across 2 of the coils so measuring 1 & 2 then 1 & 3 then 2 & 3 should all be simalar and should not read 0 or infinity.


The top picture is the drain pump motor that would be the part that might need replacing if you are having a drain pump error code. Before replacing it though I would check the windings (coils) to see it they are shorted ( 0 ohms) or burned (very high or infanate ohms). If it within range it might just be that it was not seated properly in the sump housing. The sump housing I’d the gray thing in the 2nd picture.


Hmmm, looks like the tech sheet you have is for a dishwasher that has a 3 digit 7 segment display. Odd that it would have the wrong sheet. This looks like thee correct version for your model, follow the steps that say for shx (the first part of your model number).



As I suspected this has your resistance measurements for each of the motors, so measure where indicated (power disconected) and you can see if the windings in the motor is faulty. Your selonoid value looks good.


So those are “S” not 5 as in step 1, step 2, step 3, etc if you hook it back up and start the “Customer Service Program” per the instructions at the top of the page the display will read out the step its on, it will do that step for the time indicated in the 3rd column and it will be doing the action indicated in the last column, then it will move on to the next step. This allowes you to watch and listen to each step to make sure its doing what it should. Find one that is not and you probably IDed the issue.
With the procedure listed you won’t have to touch the hot circuts, and you shouldnt, just listen and observe, make note of any action that is not doing what is described.
A “hot” circuit means one that has the power on.


984 Ohms seem kinda high for a solenoid, might be OK though, 700 to 820 ohms would seem more resonable. In the first picture there is a rolled up paper tucked under the inlet, carefully take that out and unroll it. That will be the schematic and field tech notes, it might have the solenoid nominal resistance values and probably has a trouble shooting procedure.
Edit: fixed the solenoid value typo,
Also its not the intake solenoid if it’s filling with water.
That pump motor says 3Amp 55volts AC at 215Hz that is going to be hard to bench test, and you would need the specs on the impeller to check each of the coils resistance.
Check that field tech notes and look to see if there is a diagnostic cycle that be triggered, diagnostic cycles usally allow you to step through each motor & solenoid function to see if its working. That would require putting it back together and working with it hot so don’t do it if your uncomfortable or unsure how to work on hot circuits.


Look for your brand / model sevice manual on-line, it should have troubleshooting and testing procedures as well as part # lists and replacement guides.
In the user manual I found this. Searched “Bosch Silence Plus 50 user guide”. Since they made multiple models with this name, get the model number off of the sticker on the right side on the door to refine the search.
Large food remnants in the rinsing water not
retained by the filters may block the waste
water pump.
In this case:
• Disconnect the appliance from the power supply.
• Remove the filters (see Figures 11-12).
• Scoop out standing water - use a sponge if
necessary.
• Using a spoon, pry off the pump cover (see Fig-
ures 14-15) until it clicks, then grip the cover
and pull upward until it resists and then pull
forward.
• Check inner compartment and remove any for-
eign objects.
• Place cover in the original position, press
down and engage.
• Reinstall filters.